01 Centrifuge (13 articles)
Prev[1]Next
Show: Grid Sort by:
B011  B011 Centrifuge exractor 1500/3000 G AT 3600 RPM Centrifuge exractor 1500/3000 G AT 3600 RPM
Standards : ASTM D2172, AASHTO T164A, EN 12697-1

Used for the determination of bitumen percentage in bituminous mixtures. It consists of a removable, precision machined aluminium rotor bowl, placed into a cylindrical aluminium box.

The separate control panel incorporates an electronic card fitted with AC drive which automatically drives the bowl speed rotation ramp from 0 to 3600 rpm as requested by Standards, with fast stop bowl rotation at the end of the test.

Supplied complete with speed regulator and digital display monitoring the frequency.

The centrifuge is supplied without aluminium bowl+cover and without filter discs to be ordered separately (see accessories).

The unit cannot be sold in CE markets (see mod. B011-10)
• Power supply: 230V 1ph 50-60Hz 600W
• Dimensions: 480x330x530 mm
• Weight: 50 kg approx.
• Capacity: 1500 / 3000 g

Upgrading option :
• B011-10: Safety electromegnetic micro-switch system to prevent the opening of the cover when the Centrifuge is working, or during the bowl rotation. Conforming to CE Safety Directive. Not applicable to the Centrifuge explosion proof version mod. B011-01.


Accessories :
• B010-11 Bowl and cover 1500 g capacity 
• B010-12 Bowl and cover 3000 g capacity 
• B010-15 Filter disc, 1500 g capacity 
• B010-16 Filter disc, 3000 g capacity 
• B011-10 Safety electromagnetic micro-switch system

v2022-01 B011
B011
v
B011-01  B011-01 Centriguge 1500/3000G Explosion proof Centrifuge extractor 1500g to CE directive
 B011-01.jpg
B011-01
v
B011-10  B011-10 Safety device to CE Directive Safety device to CE Directive
 B011-10.jpg
B011-10
v
B008 AUTOMATIC BINDER EXTRACTION UNIT Automatic binder extraction unit
 B008
B008
v
B008-11 B008-11 Lining paper for centrifuge cup (100 pc)dimensions Lining paper for centrifuge cup (100pc) dimensions 370x200mm
B008-11
v
B010-11 B010-11 Bowl + Cover 1500g. Bowl + Cover 1500g.
 B010-11.jpg
B010-11
v
B010-12 B010-12 Bowl + Cover 3000g Bowl + Cover 3000g
 B010-12.jpg
B010-12
v
B010-15 B010-15 Filter disc for 1500g. centrifuge (Pack of 100) Filter disc for 1500g. centrifuge (Pack of 100)
 B010-15.jpg
B010-15
v
B010-16 B010-16 Filter disc for 3000g. centrifuge (pack of 100) Filter disc for 3000g. centrifuge (pack of 100)
 B010-16.jpg
B010-16
v
B014 B014 Continous flow filterless centrifuge Continous flow filterless centrifuge
 B014
B014
v
B014-01 B014-01 Spare aluminium beaker dia. 70x200mm Spare aluminium beaker dia. 70x200mm
 B014-01.jpg
B014-01
v
B015 B015 Continous flow filterless centrifuge B015
Continuous Flow Filterless Centrifuge, 400 g capacity
( Asphalt )
EN 12697-1 ASTM D2172
It is used to perform reliable analysis on bituminous mixtures using the perchloroethylene (PCE) or tetrachloroethylene solvent which is classified: as R40 (not cancer producing*), for quantitative determination of binder or bitumen contained in pavement samples and hot mixed mixtures.

The system performs in only one complete automatic cycle:

the washing, disaggregation and separation of the bituminous mixture;
the separation of the filler from the solution formed by solvent, bitumen and filler.
The unit comprises:

A sieving unit with solvent spraying cover for washing and disaggregation of the sample;
A continuous flow filterless centrifuge having a rotation speed of 11000 rpm equipped with a stainless steel beaker Ø 120mm, filler capacity approx. 400 g;
A separate control panel allows the programming of all these functions in a fully automatic system. It is also possible to select the manual control.
This unit is supplied complete with:

Two stainless steel beakers Ø 120 mm;
Four stainless steel sieves Ø 200 mm openings: 0.063 - 0.250 - 0.800 - 2 mm;
One Sieve Frame only Ø 200 mm to improve the capacity of the first sieve;
Set of O ring gaskets for sieves.
Power supply: 400V 3ph 50Hz 5.5kW
Overall dimensions: 420x680x1630 mm
Total weight: 150 kg approx.

Note: * it is possible to use also the Trichloroethylene (CHC1:CC12), but as per the 2001/59/CE Directive, it is classified “R45”, and therefore considered a dangerous solvent. (Toxic and cancer-producing).

Note: B015 cannot be used with dichloromethane solvent. B015
B015
v
B021 B021 Solvent recovery still. 10 Litre/Hour Solvent recovery still. 10 Litre/Hour
 B021.jpg
B021
v
Prev[1]Next