Kalibraties geaccrediteerd (17 articles)
Prev[1]Next
Show: Grid Sort by:
XB104 Calibration Bending Frame Calibration between 10 and 100% of the scale under ISO17025 accreditation Belac 410-CAL following EN 12390-4 annex B with Service for a licenced Bending Frame with one channel
XB104
v
XB045 Calibration extension to 1% Extension of the calibration between 1 and 10% of one scale on one Compression Machine under ISO17025 Accreditation (Belac 410-CAL)
XB045
v
XK045 Calibration extension to 1% Extension of the calibration between 1 and 10% of one scale on one Compression Machine under ISO17025 Accreditation (Belac 410-CAL)  following EN 12390-4 annex B
XK045
v
XB105 Calibration extra Bending Frame channel on Press Calibration between 10 and 100% of an extra Bending Frame scales on one Compression Machine with more channels under ISO17025
XB105
v
XB005 Calibration extra channel on Press Calibration between 10 and 100% of an extra scales on one Compression Machine with more channels under ISO17025
XB005
v
XB005E Calibration extra channel on Press NN Calibration between 10 and 100% of an extra scales on one NN Compression Machine with more channels under ISO17025
XB005E
v
XE005 Calibration extra channel on Press no Matest Calibration between 10 and 100% of an extra scales on one Compression Machine with more channels under ISO17025 Accreditation (Belac 410-CAL)
XE005
v
XB004 Calibration Hydraulic Compression Presse one channel Calibration between 10 and 100% of the scale under ISO17025 accreditation Belac 410-CAL following EN 12390-4:2000 annex B or accourding to ISO7500-1. 
Unless on demand of the customer we calibrate following EN 12390-4 Annex B (2000)
The class determination does not take into account the measurement uncertianty.
Report will be sent after payment of invoice.
In order to be able to perform calibration under accreditation, the ambient temperature must be between 10° and 30°C. The relative humidity must be max. 80%.
XB004
v
X007E Calibration ISO 17025 Load Measuring up to 200 kN Calibration under ISO17025 accreditation of a Load Ring up to 200kN.
Certificat by a accredited laboratory after payment.
X007E
v
XB204 Calibration Large Bending Frame Calibration between 20 and 100% of the scale under ISO17025 accreditation Belac 410-CAL following EN 12390-4 annex B with Service for a licenced Large Bending Frame with one channel
XB204
v
X007XE Calibration Load Measuring up to 3000kN Calibration Load Indicating Device up to 3000 kN
X007XE
v
X007 Calibration Load Ring up to 50 kN per bereik (plaatproef) Calibration Load Ring as per range up to 50 kN
Certificat by a accredited laboratory after payment
X007
v
X007S Calibration Load Ring voor enkele kleine plaat Calibration Load Ring only one small platen
X007S
v
XB004E Calibration Presse one channel no Matest
XB004E
v
X002 X002 Accredited calibration balance max. 35kg Calibration Balance under ISO17025 Accreditation Belac Cal 410 wiè capacity between 10 g and 35 kg
calibration between 10 and 100 % of èe capacity.
Report after paiment invoice
 X002
X002
v
X002L X002L Accredited calibration balance 35 - 65 kg Calibration Balance under ISO17025 Accreditation Belac Cal 410 
Capacity between 35 and 65 kg
calibration from 10 to 100 % of capacity
 X002
X002L
v
X002XL X002XL ISO17025 calibration balance 65 - 160 kg Calibration Balance under ISO17025 Accreditation Belac Cal 410
Capacity between 65 and 160 kg
calibration from 10 to 100 % of capacity
 X002XL
X002XL
v
Prev[1]Next