02 Ultrasonic investigation (20 articles)
Prev[1]Next
Show: Grid Sort by:
P32620001    P32620001 Pundit Lab + P32620001 Pundit LAb+

The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. The Pundit Lab+ comes with an extended feature set like: compressive strength correlation, compressive strength estimation, integrated amplifier gain stage; SONBER conversion curves; real time stamp

According with standards: EN 12504-4; ASTM C 597-02; ISO 1920-7:2004; IS 13311; CECS 21
 
Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements. Pundit Lab+ removes the need for external amplification when used with exponential transducers

Common Features Pundit Lab+:
Nominal transducer frequency: 24 – 500 kHz
Transit time range: 0.1-9999 µs
Resolution: 0.1 µs
Energising pulse: 125 V, 250 V, 350 V, 500 V, AUTO
Tx frequency range: 24-500 kHz
Transit time: Yes
Pulse velocity: Yes
Path length:Yes
Surface velocity: Yes
Crack depth: Yes
Memory: > 500 readings
Power supply: Mains/Battery(>20h)/USB
New Features: Pundit Lab+
Integrated gain stage: 1x, 2x, 5x, 10x, 20x, 50x, 100x, 200x, 500x, 1000x
Compressive strength: Yes
SONREB method (Ultrasonic plus rebound hammer for compressive strength): Yes
Time stamp for measurements: Yes
Measurement review list on instrument: Yes

Consisting of: Display unit, 2 transducers (54 kHz), 2 BNC cables 1.5 m, couplant, calibration rod, USB charger with USB-cable, 4x AA batteries, data carrier with software, documentation and carrying case P32620001.jpg
P32620001
v
P32610001   P32610001 Pundit Lab P32610001 Pundit LAb

The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. 

Measurement performance; Optimized pulse shaping, automated transmission settings for optimum performance and
a range of new, more powerful transducers ensure accurate, stable measurements.
Integrated waveform display; Allows analysis of the received signal and manual triggering directly on the instrument.
On-line data acquisition; Full remote control of all transmission parameters, data logging function and functionality that turns your PC into an oscilloscope.
USB interface and data analysis software; Data analysis and export to third party programs.
Open interface; Control Pundit Lab using third party software such as LabVIEW. 

Transit time range: 0.1-9999 µs
Resolution: 0.1 µs 
Energising pulse: 125 V, 250 V, 350 V, 500 V, AUTO
Tx frequency range: 24-500 kHz
Transit time: Yes
Pulse velocity: Yes
Path length: Yes 
Surface velocity: Yes
Crack depth: Yes 
Memory: > 500 readings
Power supply: Mains/Battery(>20h)/USB 
New Features :
Integrated gain stage: 1x, 10x, 100x

Standards: EN 12504-4; ASTM C 597-02; ISO 1920-7:2004; IS 13311; CECS 21 P32610001.jpg
P32610001
v
P327 10 001   P32710001 Pundit PL-200 Ultrasonic Testing Equipment Pundit PL-200

Device is used to assess structural integrity and localize defects in concrete and rock.

The Pundit 200 is a best-in-class UPV (ultrasonic pulse velocity) test instrument with an extended range of measurement modes. Rugged touchscreen with intuitive user interface for best possible measuring and analysis of the measured data. 
 
Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement. Automatic surface velocity calculation according to standards (EN 12504-4; ASTM C 597-02; ISO 1920-7:2004). It uses ultrasonic pulse velocity technology. The same instrument can be used with pulse echo transducers.

Measuring Range: Up to 15 m depending on concrete quality
Bandwidth: 20 to 500 kHz
Measuring Resolution: 0.1 us
Nominal transducer frequency: 24 – 500 kHz

Standards: EN 12504-4, ASTM C 597-02, ISO 1920-7:2004, IS 13311, CECS 21

Includs: Case with band, Documentation, Unit Pundit PL-200, Two transducers (54kHz), Two cables (1,5 m), Software, Accessories P32710001
P327 10 001
v
P327 20 001 +202   P32720001 Pundit PL-200PE Pundit PL-200PE

The Pundit 200 Pulse Echo extends the ultrasonic application to objects where access is restricted to a single side. Major applications are slab thickness measurments and the location of voids and delaminations. 7” color rugged touchscreen with intuitive user interface. 

B-Scan is constructed directly on the instrument as the scan is carried out
Can be upgraded to Multi Channel
Same instrument can be used with classic pulse velocity transducers.
Technology: Single channel ultrasonic pulse echo

Measuring Range: Up to 1 m depending on concrete quality
Bandwidth: 20 to 500 kHz
Measuring Resolution: 0.1 us
Nominal transducer frequency: 24 – 500 kHz

Includs: Case with band, Documentation, Unit Pundit PL-200 Pulse Echo, Pulse-Echo Transducer, Cables, Software, Accessories P32720001
P327 20 001 +202
v
C369N  C369N Pocket ultrasonic concrete tester Pocket ultrasonic concrete tester
 C369N.jpg
C369N
v
C372M  C372N High performance ultrasonic tester "High performance" Ultrasonic pulse velocity tester

C372M
Ultrasonic pulse velocity tester, high performance with microprocessor for combined ultrasonic and rebound hammer data acquisition and processing. 

The appliance allows measuring:

*     Ultrasonic impulse speed inside the material, by knowing the distance between the probes; 
*     distance between the probes, by knowing the speed of the ultrasonic impulse to go through the tested material;      *     required time by the ultrasonic impulse to go through the tested material.
*     Young’s modulus, by knowing the distance between the probes and the density of the tested material
*     Crack depth
*     Zero calibration with depuration of the time for the impulse to go through the probes. 
 Calibration of a defined time value.
*      Advanced function for research purposes:
 Selection of the transmission frequency of the impulse.
 Selection of the impulse amplitude.

Possibility to use the instrument with two exponential probes, or with one standard probe and one exponential probe.

Combined ultrasonic and rebound hammer determination (sonreb method): The C372M ultrasonic tester houses an integral data logger for data acquisition, processing and store of rebound hammer values. The acquisition of the rebound values is performed with manual or automatic mode.

As for the Automatic mode, the digital Matest test hammer mod C386M is directly connected to the ultrasonic tester through a cable. The measured rebound values are automatically transmitted to the C372M tester.

The combined test allow to rectify different inaccuracies that are typical of the simple rebound hammer test, and obtaining estimates on the compressive strength of the concrete, that cannot be obtained with the ultrasonic test, granting high accuracy and reliability of the results.

The standard appliance includes:

• Instrument in basic configuration (x-scale 400MHz, 64MB Flash Memory, 64 MB Ram) in a practical and elegant palmer container.
• Two 55 kHz probes with connecting cables.
• Calibrating cylinder and contact paste 
• Strong anti shock case holding the instrument and the accessories.
• Battery pack Li-Ion 11,1V 3000 mA/per hour
• External feeder 230V/24V and battery charger

Dimensions: 400x300x180 mm.
Weight : 3 kg. C372M
C372M
v
C370-02 C370-02 Transmitting + receiving probes 55 KHZ Transmitting + receiving probes 55 KHZ
 c370-02
C370-02
v
C370-04 C370-04 Couple of cables for C372N, C373N Couple of cables for C372N, C373N
3,5m

This is the pair of the new cables length 3.5m, it allows to the connection of the probes of the tester device C372N C370-04
C370-04
v
C370-07 C370-07 Tube of grease Tube of grease
 C370-07.jpg
C370-07
v
C370-08 C370-08 Exponential probes, 55 KHZ Exponential probes. 55 KHZ
 C370-08.jpg
C370-08
v
C370-10 C370-10 Couple of cables 10m long each for C369N Couple of cables 10 m long each for C369N
 C370-10.jpg
C370-10
v
PGI RCON_GEL MEDIUM Conductive Gel - Medium Viscosity Conductive Gel - Medium Viscosity
250 ml bottle (RCON2)
PGI RCON_GEL MEDIUM
v
P325 40 177S P325 40 177S Transducers 250 kHz P325 40 177S - 2 transducers 250 kHz (2 needed for measurement)
 P325 40 177S
P325 40 177S
v
P32540150 P32540 150 Holder for transducers P32540 150 Holder for transducers

Dedicated for Pundit devices P32540150
P32540150
v
P32540176 P32540 176 transducers 54 kHz exponentional 2 Exponential transducers 54 kHz
including calibration rod P32540176
P32540176
v
P325 400 26S P32540026S 2 transducers 24 kHz 2 transducers 24 kHz

dedicated to Pundit devices P325 400 26S
P325 400 26S
v
P32540049 P32540049 2 shear transducers 250 kHz 2 shear transducers 250 kHz incl. couplant

deletion of the article 32540049 2 S-Wave Transducers, 250 kHz, incl. couplant as it has been discontinued and replaced by the article 32540210 Dry Point Shear Wave Transducer Set P32540049
P32540049
v
P32540131S P32540131S 2 Transducers 54 kHz 2 Transducers 54 kHz
 P32540131S
P32540131S
v
P32540141S P32540141S 2 transducers 250 kHz 2 transducers 150 kHz

The probe dedicated to Pundit devices P32540141S
P32540141S
v
P71010031 Ultrasound couplant, 250 ml Ultrasound couplant, 250 ml
 P71010031
P71010031
v
Prev[1]Next